14 VIX IM MICROSTEPPER INDEXER DRIVE USER GUIDE
XL-PSU Supply/Drive Connections
When used to supply up to two drives the power supply can be wired as shown in Figure 3-3.
-DC
+24V
P1
P2
N
L
MAINS
INPUT
110V-230V~
50/60 Hz
250VA
Power
Supply
Unit
XL
GND
EXT. BRAKING RES.
+DC (80V)
HV STATUS
BRAKING RES.
24V STATUS
X2
X3
X1
X4
X5
ST
HV FB
10
1
10
1
10 mm
Mininum spacing
between drives & PSU
LN
EARTH (GND.)
The XL_PSU must
be securely earthed
P2 mating socket
If the supply is positioned
this side of the drive
avoid blocking access to
D-type X3
Figure 3-3. XL Power Supply and Drive Connections
Note: A kit of five connecting links is available, called XL-connect. You will need one kit for
every drive.